Built to order · 44 assemblies

Circular M-Series Cable Assemblies

Round connector leads for industrial sensor and actuator wiring, covering A-coded M8 in 3 to 6 pin and A-coded M12 in 3 to 8 pin, straight or right-angle, with PVC, PUR or TPU jackets. Sealed to IP65–IP67 when mated and built to IEC 61076-2-101 (M12) and IEC 61076-2-104 (M8). The range also extends past M8 and M12 to M5 miniature sensor cordsets, M16 sensor and actuator builds, M20 locking power and signal leads and M23 encoder feedback and servo power assemblies. Pin count, length, orientation, jacket and shielding are set per order.

Connector
M5 · M8 · M12 · M16 · M20 · M23
Pin count
M5 3–4 · M8 3–6 · M12 3–12 · M16 2–14 · M23 6–19
Orientation
Straight · 90° right-angle
Sealing
IP65 – IP67 mated
Jacket
PVC · PUR · TPU
Shielding
Unshielded · foil + braid
Length
0.3 m – 30 m
Standard
IEC 61076-2-101 / -104

Showing 13–24 of 61 results

M12 A-Code 4-Pin Y-Splitter Sensor / Actuator Cable

This M12 y splitter sensor cable turns one four-position A-coded port into two, so one home run feeds two sensors or actuators. IEC 61076-2-101, IP67 molded Y block, 4 A / 60 V DC, PVC or PUR. Size the trunk for both loads.

M12 A-Code Push-Pull Sensor Cable, IP67

This m12 push pull cable keeps the A-coded sensor pinout the industry knows and swaps the screw thread for a push-pull coupling: press the shells together and the retaining latch locks, so a connection that took several turns now takes a second.

M12 A-Coded PVC/PUR Straight or Right-Angle Extension Cable

This M12 PVC PUR cable is offered in straight or right-angle A-coded bodies with 3 to 8 positions, so the two decisions are jacket compound and exit direction. PVC for dry enclosures, PUR for oil, coolant, UV and flexing runs. Built to length.

M12 B-Coded PROFIBUS Cable, 5-Pin Fieldbus Cordset

An M12 B-coded PROFIBUS cable with the keyway reversed relative to A-code, so a sensor lead cannot be pushed into a bus port. Five-pin shielded pair, braid bonded to the coupling nut, for bus-in, bus-out or spur drops on existing DP segments.

M12 C-Coded AC Cable, Dual Keyway for AC Sensors and Actuators

An M12 C-coded AC cable for the mains-voltage branch of a machine: dual keyway that refuses an A-coded plug, and an extended protective earth contact that makes first and breaks last. 3 to 6 poles, mains-rated jacket, made to your length.

M12 CAN Bus Cable, 5-Pin Shielded Pair for CANopen and DeviceNet

An M12 CAN bus cable built for stable CANopen and DeviceNet segments: one shielded twisted pair held at a controlled lay, the braid bonded to the coupling nut at both ends, and supply cores where the drop powers the node. Built to the pinout you send.

M12 D-Code 4-Pin PROFINET Industrial Ethernet Cable

This M12 PROFINET cable runs 100 Mbit/s industrial Ethernet from a D-coded IP67 device port to a shielded RJ45 in the cabinet. Cat5e SF/UTP, 24 AWG stranded, green PUR jacket, pin 1 TD+ through pin 4 RD-. Built to your length.

M12 Drag Chain Cable, Continuous Flex Cordset for Cable Carriers

An M12 drag chain cable built around the carrier radius, travel length and cycle target your machine actually runs. Fine-strand high-flex copper, high-flex PUR jacket and a braid bonded to the coupling nut - send the motion data and we build to it.

M12 Hybrid SPE Cable for Actuators and Valve Islands

An M12 hybrid SPE cable puts a single pair Ethernet link and two or four power contacts in one shell, so a valve island or actuator needs one cable instead of two. IEC 63171-7 class face, built to your pinout and length.

M12 IO-Link Cable, Master to Device Drop for 3 and 4 Wire Ports

An M12 IO-Link cable for master-to-device drops on 3-wire and 4-wire installations, built for port class A or port class B. Conductors sized to your drop length rather than picked from a default, so the device still sees a healthy supply at the far end.

M12 IP68 / IP69K Food-Grade Stainless Steel Washdown Cable

This M12 ip69k food grade cable is specified against the washdown cycle rather than the load: stainless 316L coupling nut, seals chosen for the detergent, TPE or halogen-free PUR jacket. IP68 and IP69K per ISO 20653, -40 to +105 C, built to length.

M12 IP69K Washdown Cable with Stainless Steel Coupling Nut

An M12 IP69K washdown cable with a stainless steel coupling nut survives high pressure hot water, caustic foam and daily thermal cycling. D-coded or X-coded, silicone-free halogen-free jacket, built to your length and pinout.

Specification table

Every cordset below is assembled after the order is placed, so the specification is written backwards from your connector, your controller and the environment the cable runs through. If your pin count, cable chemistry or approval list is not in the table, it is still buildable unless the molding geometry forbids it, in which case you hear that before tooling starts.

Typical M8 and M12 circular cordset build options. Every assembly is made to order, so values outside this table are quoted rather than declined.
ParameterStandard buildAvailable on request
Connector seriesM8 A-coded 3-6 pin; M12 A-coded 3-12 pinM5, M16, M20, M23 and 7/8 in builds
CodingA (sensor), B (PROFIBUS), D (PROFINET), X (Cat6A)K, S, T, L, M power and Y hybrid
Shell couplingM8 x 0.5 and M12 x 1 threaded per IEC 61076-2-101 / -104Push-pull, stainless V4A, weld-slag resistant shells
Body styleStraight and 90° right-angle, rotatable to orderClocked exits so both plugs face the same way
Conductor22-26 AWG stranded copper per pin20 AWG power pairs, hybrid power plus data
ShieldingUnshielded as standardFoil plus braid bonded 360° to the coupling nut
JacketPVC (control cabinet), PUR (oil and coolant)TPU drag chain, weld-spatter, food-grade
SealingIP65 to IP67 matedIP68 continuous immersion, IP69K washdown
Length0.3 m to 30 m, set per orderRobot dress-out assemblies and coiled lengths
MarkingPrinted or laser part numberCable flags, port numbering, customer artwork

Mating hardware is compliant with IEC 61076-2-101 for M12 and IEC 61076-2-104 for M8; fieldbus and device-side behavior follows the relevant profile from IO-Link or PROFIBUS.

M8 or M12 — which thread fits the job

The two share the same insert family. The decision usually comes down to available panel space and how often the connection is made and broken.

M8 against M12 for sensor and fieldbus wiring.
ParameterM8M12
Thread and cut-out8 mm, M8×1 or PG7 thread12 mm, M12×1 or PG9 thread
Pin count3, 4, 5 or 6 pin3, 4, 5, 8, 12 pin
Current per pinUp to 3 AUp to 4 A, higher on power-coded inserts
Typical useCompact sensor heads, small junction boxes, tight manifoldsGeneral sensor wiring, IO-Link ports, fieldbus drops
Mating cyclesAround 100500 and up
Choose whenThe device body has no room for a 12 mm threadThe run sees vibration, washdown or repeated disconnection

Typical applications

  1. Sensor and actuator drops Discrete I/O wiring from the junction block to inductive, photo and pressure sensors, where the M12 nut is expected to survive thousands of service cycles.
  2. IO-Link and PROFINET Class A ports carrying both power and switched data on one four or five pin cordset rather than a separate power pair.
  3. Drag chain and robot dress-out High-flex TPU builds with put-up lengths tuned to the axis travel.
  4. Food, beverage and washdown Stainless coupling nuts and PUR or TPU jackets rated for daily caustic rinse.
  5. Machine vision M12 X-coded Cat6A leads feeding GigE Vision cameras on moving gantries.

Related reading

Questions buyers ask

Which M12 coding should I specify?

A-coded carries sensor signals and is the most common by far. D-coded is for 100 Mbit Ethernet and PROFINET, X-coded is the Cat6A version used by GigE Vision cameras, and B-coded still appears on older PROFIBUS drops. K, S, T, L and M-coded are power variants with a different keyway so a signal plug cannot be forced into a power socket. The full code list is in our M12 coding guide.

Do you verify the IP rating on every unit?

Every mated pair is checked for shell seating and strain relief pull. Immersion and washdown claims are tested per construction during qualification, and we state which method was used rather than quoting a number with no test behind it. The practical differences are set out in our ingress rating guide.

Can I mix straight and right-angle ends on one cordset?

Yes, and that is the usual request. Give us the clocking angle if it matters, otherwise both plugs are molded in the same orientation with the molded bodies aligned when the cable lies flat.

Have one built to your drawing

Send the connector part numbers, lengths and environment. We review manufacturability in writing before any tooling spend, and we tell you up front what we cannot do.

Request a quote