Built to order · 28 assemblies

Ethernet Patch Cords and Industrial Network Cables

Copper patch leads from Cat5e to Cat8 in UTP, S/FTP and high-flex PUR, with industrial variants using M12 X-coded, ix Industrial and 10BASE-T1L single pair endpoints. Category, shielding, jacket and boot style are set per order.

Category
Cat5e · Cat6 · Cat6A · Cat8
Shielding
UTP · S/FTP · F/FTP
Industrial
M12 X-code · ix Industrial
Single pair
10BASE-T1L · T1 / M8
Jacket
PVC · PUR · LSZH · gel-filled
Rating
IP67 · IP68 · IP69K
Conductor
22 – 28 AWG
Length
0.3 m – 30 m

Showing 1–12 of 36 results

10BASE-T1L Patch Cord for Single Pair Ethernet, T1 Industrial or M8

A 10BASE-T1L patch cord for single pair Ethernet field trunks, carrying 10 Mbit/s up to 1000 m on one pair with optional power over the data line. T1 Industrial or M8 ends, IP20 or IP67, built to your length and pinout.

Cat5e CMP Plenum Patch Cord

A cat5e cmp plenum cord is rated for air handling spaces: CMP and FT6 to UL 910, 24 AWG solid copper, low smoke flame retardant jacket for drops above ceilings and under raised floors.

Cat5e FTP Outdoor / Direct-Burial Patch Cord (24 AWG Solid, LLDPE, IP67)

A cat5e ftp outdoor direct burial patch cord on an LLDPE UV-resistant jacket with an overall foil shield, built for above-ground, conduit and buried runs.

Cat5e FTP Shielded Patch Cord

A cat5e ftp shielded cord puts a 100 percent foil screen over the four pairs and terminates it into screened RJ45 plugs, for runs that pass drives, lighting, lift machinery or dense trays.

Cat5e UTP Crossover Patch Cord (T568A to T568B, 24 AWG Stranded, 100 MHz)

A cat5e utp crossover patch cord wired T568A on one end and T568B on the other, for direct links between two like devices on hardware with no Auto-MDIX.

Cat5e UTP etherCON Patch Cord (Neutrik NE8MC Rugged Locking, Touring-Grade)

A cat5e utp ethercon patch cord with rugged locking RJ45 carriers on both ends, for touring, stage and studio runs where a standard latch does not survive.

Cat5e UTP LSZH Patch Cord (350 MHz, 24 AWG Stranded, IEC 60754 / 61034)

A cat5e utp lszh patch cord on a low-smoke zero-halogen jacket, for occupied and public spaces where smoke and acid gas are the specification, not the data rate.

Cat5e UTP Patch Cord

A cat5e utp cord is the everyday link between a switch, a patch panel, a wall outlet and the device at the end of the run. Four 24 AWG solid pairs, RJ45 to RJ45, snagless boot.

Cat5e UTP Retractable Patch Cord (350 MHz, 24 AWG, Auto-Wind Reel, T568B)

A cat5e utp retractable patch cord on a compact auto-wind reel, 24 AWG stranded copper, T568B and snagless boot. For benches, service kits and demo setups.

Cat5e UTP Short-Body Patch Cord for VoIP (350 MHz, 24 AWG, Slim RJ45 Boot)

A cat5e utp short body voip patch cord with a slim RJ45 boot for the places a standard boot will not seat: 48-port panels, VoIP desk phones and shallow wall boxes.

Cat5e UTP Snagless Patch Cord (350 MHz, 24 AWG Stranded, T568B, 4-Pair, 50u” Gold)

A cat5e utp snagless patch cord in stranded 24 AWG bare copper, T568B, 50 micro-inch gold RJ45, with a molded boot that stops the latch snapping in a full panel.

Cat6 CMP Plenum-Rated Patch Cord (550 MHz, 23 AWG Solid, NFPA 262, FT6)

A cat6 cmp plenum rated patch cord for air-handling spaces: above drop ceilings, under raised floors and inside ducts, where the code requires a plenum marking.

Specification table

Patch cords look interchangeable until the environment changes the requirement: office cabinet work needs flexible stranded conductors, industrial runs need PUR or LSZH jackets and locking plugs, and anything single pair needs its own budget. We build all three from the same drawing discipline.

Typical Ethernet patch cord build options. Every assembly is made to order, so values outside this table are quoted rather than declined.
ParameterStandard buildAvailable on request
CategoryCat5e, Cat6, Cat6A, Cat8Cat6A S/FTP for 10GBASE-T over full distance
Conductor22-28 AWG stranded for patch useSolid conductor where the run is punched down
ShieldingUTP (office), F/UTP (noisy mixed runs)S/FTP with individually shielded pairs
IndustrialM12 X-coded and ix IndustrialRJ45 with IP67 bayonet protection
Single pair10BASE-T1L and T1 / M8 buildsSPE bulkhead versions
JacketPVC, LSZH, PURGel-filled for direct burial, CM/CMR ratings
RatingIP67 mated where the hardware is sealedIP68 and IP69K with the matching receptacle
Length0.3 m to 30 mHarnesses with multiple labeled drops
StandardsISO/IEC 11801 and TIA-568 channel classesChannel versus permanent link clarification

Cabling channel performance follows ISO/IEC 11801; M12 connectors remain built to IEC 61076-2-101.

Typical applications

  1. Data center and office cabinets Short, flexible, correctly terminated cords that do not drag their neighbors.
  2. Industrial Ethernet M12 X-coded and ix Industrial runs built for vibration and coolant.
  3. Machine vision Cat6A lines feeding GigE Vision cameras on moving equipment.
  4. Touring and broadcast Ruggedized cords that survive repeated set and strike.
  5. Building networks LSZH and CMR rated riser runs.

Related reading

Questions buyers ask

Cat5e, Cat6 or Cat6A?

Cat5e is fine for gigabit at short reach. Cat6 buys headroom against alien crosstalk in dense bundles, and Cat6A is the realistic choice for 10GBASE-T over 100 m. Our patch cord comparison puts numbers on each step.

When is single pair Ethernet the better answer?

When a sensor node needs power and a modest data rate over a longer distance on thinner cable. It trades throughput for reach and weight. See SPE versus four-pair Ethernet.

RJ45 or M12 X-coded on the machine?

If the equipment is cleaned, moved or vibrated, M12 X-coded is the connector engineers specify, and we build both plus the adapter leads between them. Details in this comparison.

Have one built to your drawing

Send the connector part numbers, lengths and environment. We review manufacturability in writing before any tooling spend, and we tell you up front what we cannot do.

Request a quote