Cat6 CMP Plenum-Rated Patch Cord (550 MHz, 23 AWG Solid, NFPA 262, FT6)
CMP / FT6 plenum-rated Cat6 UTP patch cord with 23 AWG solid bare copper, 550 MHz, T568B, 50 micro-inch gold RJ45. Approved for use in air-handling spaces – above drop ceilings, below raised floors and inside HVAC ducts – where NFPA 70 / NFPA 262 CMP-rated cable is required.
Category: Ethernet cable patch cord
Description
Overview
CMP / FT6 plenum-rated Cat6 UTP patch cord with 23 AWG solid bare copper, 550 MHz, T568B, 50 micro-inch gold RJ45. Approved for use in air-handling spaces – above drop ceilings, below raised floors and inside HVAC ducts – where NFPA 70 / NFPA 262 CMP-rated cable is required.
Key Features
- 4-pair 100 Ohm twisted-pair construction, ETL/UL / standards verified
- 50 micro-inch gold-plated RJ45 8P8C contacts for low insertion loss
- Snagless molded boot protects the latch and eases high-density patching
- 100% bare-copper conductor (no CCA) – PoE / PoE+ / PoE++ safe
- Custom lengths, colours and branding available on request
Typical Applications
- Data-centre and server-room patching
- Office LAN, workstation, VoIP and Wi-Fi AP drops
- Structured-cabling patch-panel to switch links
- IP cameras, access control and building-automation links
Specifications
| Cable Type | Cat6 UTP |
|---|---|
| Plenum Rating | CMP / FT6 (NFPA 262) |
| Conductor | 23 AWG Solid Bare Copper |
| Bandwidth | 550 MHz |
| Wiring | T568B |
| Connector | RJ45 Long-Body Male, 50 uin Gold-Plated |
| Jacket | Plenum PVC (Low-Smoke) |
| Cable Diameter | 6.0 mm |
| Operating Temperature | -10 °C to +75 °C |
| Compliance | c(UL)us, TIA/EIA-568-C.2, ISO/IEC 11801, NFPA 262 |
Packaging
- 1 piece per PE bag; 50 / 100 pieces per export carton
- Custom retail box, label and bar-code available
Notes
- All specifications are typical values unless otherwise stated and subject to change without notice.
- For PoE++ Type 3 / Type 4 (60 W / 90 W) deployment, ensure bundle size and ambient temperature follow TIA TSB-184-A guidelines.
- Storage temperature: -20 °C to +70 °C. Do not install below -10 °C jacket rating.
Additional information
| Cable Type | Cat6 UTP |
|---|---|
| Plenum Rating | CMP / FT6 (NFPA 262) |
| Conductor | 23 AWG Solid Bare Copper |
| Bandwidth | 550 MHz |
| Wiring | T568B |
| Connector | RJ45 Long-Body Male, 50 uin Gold-Plated |
| Jacket | Plenum PVC (Low-Smoke) |
| Cable Diameter | 6.0 mm |
| Operating Temperature | -10 °C to +75 °C |
| Compliance | c(UL)us, TIA/EIA-568-C.2, ISO/IEC 11801, NFPA 262 |